32 Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Reference
2 Commands Quick Reference
:EXTernal:PROBe
<attenuation> (see
page 175)
:EXTernal:PROBe? (see
page 175)
<attenuation> ::= probe
attenuation ratio in NR3 format
n/a :EXTernal:PROBe:ID?
(see page 176)
<probe id> ::= unquoted ASCII
string up to 11 characters
:EXTernal:PROBe:STYPe
<signal type> (see
page 177)
:EXTernal:PROBe:STYPe
? (see page 177)
<signal type> ::= {DIFFerential |
SINGle}
:EXTernal:PROTection[
:CLEar] (see
page 178)
:EXTernal:PROTection?
(see page 178)
{NORM | TRIP}
:EXTernal:RANGe
<range>[<suffix>]
(see page 179)
:EXTernal:RANGe? (see
page 179)
<range> ::= vertical full-scale
range value in NR3 format
<suffix> ::= {V | mV}
:EXTernal:UNITs
<units> (see
page 180)
:EXTernal:UNITs? (see
page 180)
<units> ::= {VOLT | AMPere}
Table 8 :EXTernal Trigger Commands Summary (continued)
Command Query Options and Query Returns
Table 9 :FUNCtion Commands Summary
Command Query Options and Query Returns
:FUNCtion:CENTer
<frequency> (see
page 183)
:FUNCtion:CENTer?
(see page 183)
<frequency> ::= the current
center frequency in NR3 format.
The range of legal values is from
0 Hz to 25 GHz.
:FUNCtion:DISPlay {{0
| OFF} | {1 | ON}}
(see page 184)
:FUNCtion:DISPlay?
(see page 184)
{0 | 1}
:FUNCtion:OFFSet
<offset> (see
page 185)
:FUNCtion:OFFSet?
(see page 185)
<offset> ::= the value at center
screen in NR3 format.
The range of legal values is
+/-10 times the current
sensitivity of the selected
function.
:FUNCtion:OPERation
<operation> (see
page 186)
:FUNCtion:OPERation?
(see page 186)
<operation> ::= {SUBTract |
MULTiply | INTegrate |
DIFFerentiate | FFT | SQRT}