Agilent Technologies 6814B Welding System User Manual


 
IEC Mode Command Summary - E
179
SYSTem:CONFigure
Agilent 6812B, 6813B, 6843A Only
This command sets the overall operating mode of the ac source. The choices are Normal mode, which
causes the product to closely mimic the operating characteristics of standard ac sources, or IEC mode,
which modifies the basic behavior of the transient and measurement systems to facilitate IEC
measurements. SYSTem:CONFigure has a variety of global consequences that are summarized below:
NORMAL MODE IEC MODE
Base Sampling Rate
39.920792 KHz 38.400000 KHz
Output Frequency
DC - 1000 Hz 50 Hz & 60 Hz Only
Freq/Window/Fs Mode
Independent Coupled
Transient System
FIXEd/STEP/PULSe/LIST
Modes
FIXEd Mode Only
Slew Operation
AC & DC Voltage; Frequency AC Voltage Only
MEASure:ARRay:CURRent
:HARM?
DC, Fundamental, and
Harmonics to 50th
Fundamental and Harmonics
to 40th plus RMS Current,
RMS Voltage & Real Power
CALCulate:SMOothing
Not/Available 1.5 Second Smoothing on/off
MEASure:ARRay:VOLTage
:FLUCtuations
Not/Available FLICker | PST | ALL?
CALCulate:INTegral:TIME
Not/Available 1 | 5 | 10 | 15 MINutes
Transmission of a SYSTem:CONFigure command implies ABORt and terminates any transient or
measurement actions previously initiated.
Command Syntax
SYSTem:CONFigure <CRD>
Parameters
NORMal | IEC
*RST Value
NORMal
Examples
SYST:CONF NORM
Query Syntax
SYSTem:CONFigure?
Returned Parameters
<CRD>
Related Commands
ABORt MEAS:ARR:CURR MEAS:ARR:VOLT CALC:SMO
CALC:INT SENS:WIND