Agilent Technologies 6814B Welding System User Manual


 
3 - Language Dictionary
84
PULSe:PERiod
This command sets the period of a triggered output transient The command parameters are model-
dependent.
Command Syntax
[SOURce:]PULSe:PERiod <NRf+>
Parameters
3-phase models: 0 to 1.07533E6 | MINimum | MAXimum
1-phase models: 0 to 4.30133E5 | MINimum | MAXimum
Unit
S
(seconds)
*RST Value
.03333
Examples
PULS:PER 0.001 PULS:PER MIN
Query Syntax
[SOURce:]PULSe:PERiod?
Returned Parameters
<NR3>
Related Commands
PULS:COUN PULS:DCYC PULS:PER PULS:HOLD
PULSe:WIDTh
This command sets the width of a transient output pulse. The command parameters are model-
dependent.
Command Syntax
[SOURce:]PULSe:WIDTh <NRf+>
Parameters
3-phase models: 0 to 1.07533E6 | MINimum | MAXimum
1-phase models: 0 to 4.30133E5 | MINimum | MAXimum
Unit
S
(seconds)
*RST Value
.01667 (equals the period of a single 60 Hz cycle)
Examples
PULS:WIDT 0.001 PULS:WIDT MIN
Query Syntax
[SOURce:]PULSe:WIDTh?
Returned Parameters
<NR3>
Related Commands
PULS:COUN PULS:DCYC PULS:PER PULS:HOLD