Language Dictionary - 3
99
Bit Configuration of Questionable Instrument Summary Registers
Bit
Position
15–13 12 11 10 9 8–5 4 3 2 1 0
Bit Name not
used
CL
rms
Rail not
used
RI not
used
OT UNR not
used
OCP OV
Bit Weight 4096 2048 512 16 8 2 1
OV over-voltage protection has tripped
OCP over-current protection has tripped
UNR output is unregulated
OT over-temperature protection has tripped
RI remote inhibit is active
Rail rail protection tripped (Agilent 6811B, 6812B, 6813B);
rail voltage unregulated (Agilent 6814B, 6834B, 6843A)
CL rms rms current limit is active
STATus:QUEStionable:INSTrument:ISUMmary?
Agilent 6834B Only
Phase Selectable
This command returns the value of the Questionable Event register for a specific output of a three-phase
ac source. The particular output phase must first be selected by INST:NSEL.
The Event register is a read-only register which holds (latches) all events that are passed by the
Questionable NTR and/or PTR filter. Reading the Questionable Event register clears it.
Query Syntax
STATus:QUEStionable:INSTrument:ISUMmary[:EVENt]?
Parameters
None
Examples
STAT:QUES:INST:ISUM:EVEN?
Returned Parameters
<NR1> (register value)
Related Commands
*CLS INST:NSEL STAT:QUES:INST:ISUM:NTR
STAT:QUES:INST:ISUM:PTR