Agilent Technologies 6814B Welding System User Manual


 
3 - Language Dictionary
76
LIST:STEP
This command specifies how the list sequencing responds to triggers. The following parameters may be
specified:
ONCE
causes the list to advance only one point after each trigger. Triggers that arrive during a
dwell delay are ignored
AUTO
causes the entire list to be output sequentially after the starting trigger, paced by its dwell
delays. As each dwell delay elapses, the next point is immediately output
Command Syntax
[SOURce:]LIST:STEP <step>
Parameters
ONCE | AUTO
*RST Value
AUTO
Examples
LIST:STEP ONCE
Query Syntax
[SOURce:]LIST:STEP?
Returned Parameters
<CRD>
Related Commands
LIST:COUN LIST:DWEL
LIST:TTLTrg
This command sets the sequence of Trigger Out list points. Each point which is set ON will cause a pulse
to be output at Trigger Out when that list step is reached. Those entries which are set OFF will not
generate Trigger Out pulses.
The order in which the list points are given determines the sequence in which Trigger Out pulses will be
output when a list is triggered. Changing list data while a subsystem is in list mode generates an implied
ABORt.
Command Syntax
[SOURce:]LIST:TTLTrg <bool> {,<bool>}
Parameters
0 | 1 | OFF | ON
Examples
LIST:TTLT 1,0,1 LIST:TTLT ON,OFF,ON
Query Syntax
[SOURce:]LIST:TTLTrg?
Returned Parameters
0 | 1 {,0 | 1}
Related Commands
LIST:TTLT:POIN? LIST:COUN LIST:DWEL LIST:STEP
OUTP:TTLT OUTP:TTLT:SOUR
LIST:TTLTrg:POINts?
This query returns the number of points specified in LIST:TTLT. Note that it returns only the total number
of points, not the point values.
Query Syntax
[SOURce:]LIST:TTLTrg:POINTs?
Returned Parameters
<NR1>
Examples
LIST:TTLT:POIN?
Related Commands
LIST:TTLT