VOLTage:OFFSet:SLEW
Agilent 6811B, 6812B, 6813B, Only
This command sets the slew rate for all programmed changes in dc output voltage. A parameter of
MAXimum or INFinity sets the slew to its maximum possible rate. The SCPI representation for INFinity is
9.9E37.
Command Syntax
[SOURce:]VOLTage:OFFSet:SLEW[:IMMediate] <NRf+> | INFinity
Parameters
0 to 9.9E37 | MAXimum | MINimum | INFinity
Unit
V
(volts per second)
*RST Value
INFinity
Examples
VOLT:OFFS:SLEW 50 VOLT:OFFS:SLEW MAX
Query Syntax
[SOURce:]VOLTage:OFFSet:SLEW[:IMMediate]?
Returned Parameters
<NR3>
Related Commands
VOLT:OFFS:MODE OUTP:COUP
VOLTage:OFFSet:SLEW:MODE
Agilent 6811B, 6812B, 6813B, Only
This command determines how the dc offset slew rate is controlled during a triggered output transient.
The choices are:
FIXed
The offset slew rate is unaffected by a triggered output transient.
STEP
The offset slew rate is programmed to the value set by
VOLTage:OFFSet:SLEW:TRIGgered when a triggered transient occurs.
PULSe
The offset slew rate is changed to the value set by VOLTage:OFFSet:SLEW:TRIGgered
for a duration determined by the pulse commands.
LIST
The offset slew rate is controlled by the voltage offset slew list when a triggered transient
occurs.
Command Syntax
[SOURce:]VOLTage:OFFSet:SLEW:MODE <mode>
Parameters
FIXed | STEP | PULSe | LIST
*RST Value
FIXed
Examples
VOLT:OFFS:SLEW:MODE STEP
Query Syntax
[SOURce:]VOLTage:OFFSet:SLEW:MODE?
Returned Parameters
<CRD>
Related Commands
VOLT:OFFS:SLEW VOLT:OFFS:SLEW:TRIG