3 - Language Dictionary
86
VOLTage
Phase Selectable
This command programs the ac rms output voltage level of the ac source.
The maximum peak voltage that the ac source can output is 425 V peak. This includes any combination of
voltage, voltage offset, and function shape values. Therefore, the maximum value that can be
programmed depends on the peak-to-rms ratio of the selected waveform. For a sinewave, the maximum
voltage that can be programmed is 300 V rms.
NOTE: For Agilent models 6814B, 6834B and 6843A, you cannot program a voltage that
produces a higher volt-second on the output than a 300 Vrms sinewave.
Command Syntax
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Parameters
For sinewaves: 0 to 300 | MAXimum | MINimum
Unit
V
(rms voltage)
*RST Value
1
Examples
VOLT 115 VOLT:LEV 250
Query Syntax
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]?
Returned Parameters
<NR3>
Related Commands
VOLT:MODE VOLT:TRIG VOLT:OFFS FUNC:SHAP
VOLTage:TRIGgered
Phase Selectable
This command selects the ac rms amplitude that the output waveform will be set to during a triggered step
or pulse transient.
The maximum peak voltage that the ac source can output is 425 V peak. This includes any combination of
voltage, voltage offset, and function shape values. Therefore, the maximum value that can be
programmed depends on the peak-to-rms ratio of the selected waveform. For a sinewave, the maximum
voltage that can be programmed is 300 V rms.
NOTE: For Agilent models 6814B, 6834B and 6843A, you cannot program a voltage that
produces a higher volt-second on the output than a 300 Vrms sinewave.
Command Syntax
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] <NRf+>
Parameters
For sinewaves: 0 to 300 | MAXimum | MINimum
Unit
V
(rms voltage)
*RST Value
1
Examples
VOLT:TRIG 120 VOLT:LEV:TRIG 150
Query Syntax
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]?
Returned Parameters
<NR3> (if the trigger level is not programmed, the immediate
level is returned)
Related Commands
VOLT VOLT:MODE VOLT:OFFS FUNC:SHAP