Language Dictionary - 3
87
VOLTage:MODE
Phase Selectable
This command determines how the ac rms output voltage is controlled during a triggered output transient.
The choices are:
FIXed
The voltage is unaffected by a triggered output transient.
STEP
The voltage is programmed to the value set by VOLTage:TRIGgered when a triggered
transient occurs.
PULSe
The voltage is changed to the value set by VOLTage:TRIGgered for a duration determined
by the pulse commands.
LIST
The voltage is controlled by the voltage list when a triggered transient occurs.
Command Syntax
[SOURce:]VOLTage:MODE <mode>
Parameters
FIXed | STEP | PULSe | LIST
*RST Value
FIXed
Examples
VOLT:MODE FIX VOLT:MODE:LIST
Query Syntax
[SOURce:]VOLTage:MODE?
Returned Parameters
<CRD>
Related Commands
VOLT VOLT:TRIG
VOLTage:OFFSet
Agilent 6811B, 6812B, 6813B, Only
This command programs the dc output voltage level of the ac source.
The maximum peak voltage that the ac source can output is 425 V peak. This includes any combination of
voltage, voltage offset, and function shape values. Therefore, the maximum value that can be
programmed depends on the peak-to-rms ratio of the selected waveform. For a sinewave, the maximum
voltage that can be programmed is 300 V rms.
NOTE: The OUTPut:COUPling must be set to DC to get non-zero dc output.
Command Syntax
[SOURce:]VOLTage:OFFSet[:IMMediate] <NRf+>
Parameters
–425 to +425 | MAXimum | MINimum
Unit
V
(dc voltage)
*RST Value
0
Examples
VOLT:OFFS 100
Query Syntax
[SOURce:]VOLTage:OFFSet[:IMMediate]?
Returned Parameters
<NR3>
Related Commands
VOLT:OFFS:MODE OUTP:COUP FUNC:SHAP