Agilent Technologies 6814B Welding System User Manual


 
Language Dictionary - 3
69
FUNCtion:MODE
This command determines how the waveform shape is controlled during a triggered output transient. The
choices are:
FIXed
The waveform shape is unaffected by a triggered output transient.
STEP
The waveform shape is programmed to the value set by FUNCtion:TRIGgered when a
triggered transient occurs.
PULSe
The waveform shape is changed to the value set by FUNCtion:TRIGgered for a duration
determined by the pulse commands.
LIST
The waveform shape is controlled by the waveform shape list when a triggered transient
occurs.
Command Syntax
[SOURce:]FUNCtion[:SHAPe]:MODE <mode>
Parameters
FIXed | STEP | PULSe | LIST
*RST Value
FIXed
Examples
FUNC:MODE FIX
Query Syntax
[SOURce:]FUNCtion[:SHAPe]:MODE?
Returned Parameters
<CRD>
Related Commands
FUNC FUNC:TRIG
FUNCtion:TRIGgered
This command selects the shape of the output voltage waveform when a triggered step or pulse transient
occurs. The parameters are:
SINusoid
A sinewave is output
SQUare
A squarewave is output
CSINusoid
The output is a clipped sinewave. Both positive and negative peak amplitudes are clipped
at a value determined by the FUNCtion:CSINusoid command.
<table>
The output shape is described by one of the user-defined waveform tables.
The maximum peak voltage that the ac source can output is 425 V peak. This includes any combination of
voltage, voltage offset, and function shape values. Therefore, the maximum value that can be
programmed depends on the peak-to-rms ratio of the selected waveform. For a sinewave, the maximum
voltage that can be programmed is 300 V rms.
NOTE: For Agilent models 6814B, 6834B and 6843A, you cannot program a voltage that
produces a higher volt-second on the output than a 300 Vrms sinewave.
Command Syntax
[SOURce:]FUNCtion[:SHAPe]:TRIGgered <shape>
Parameters
SINusoid | SQUare | CSINusoid | <table>
*RST Value
SINusoid
Examples
FUNC:TRIG SIN FUNC:TRIG TABLE1
Query Syntax
[SOURce:]FUNCtion[:SHAPe]:TRIGgered?
Returned Parameters
<CRD>
Related Commands
FUNC FUNC MODE VOLT