3 - Language Dictionary
92
VOLTage:SENSe:SOURce
VOLTage:ALC:SOURce
These commands select the source from which the output voltage is sensed. The commands are
interchangeable; they both perform the same function. The following voltage sense sources can be
selected:
INTernal
This senses the voltage at the output of the power amplifier on the inboard side of the
output disconnect relay.
EXTernal
This senses the output voltage at the rear panel voltage sense terminals, which allows
remote voltage sensing at the load.
Command Syntax
[SOURce:]VOLTage:SENSe:SOURce <source>
[SOURce:]VOLTage:ALC:SOURce <source>
Parameters
INTernal | EXTernal
*RST Value
INTernal
Examples
VOLT:SENS:SOUR INT VOLT:ALC:SOUR EXT
Query Syntax
[SOURce:]VOLTage:SENSe:SOURce?
[SOURce:]VOLTage:ALC:SOURce?
Returned Parameters
<CRD>
Related Commands
VOLT:SENS:DET
VOLTage:SLEW
Phase Selectable
This command sets the slew rate for all programmed changes in the ac rms output voltage level of the ac
source. A parameter of MAXimum or INFinity sets the slew to its maximum possible rate. The SCPI
representation for INFinity is 9.9E37.
Command Syntax
[SOURce:]VOLTage:SLEW[:IMMediate] <NRf+> | INFinity
Parameters
0 to 9.9E37 | MAXimum | MINimum | INFinity
Unit
V
(volts per second)
*RST Value
INFinity
Examples
VOLT:SLEW 50 VOLT:SLEW INF
Query Syntax
[SOURce:]VOLTage:SLEW[:IMMediate]?
Returned Parameters
<NR3>
Related Commands
VOLT:SLEW:MODE VOLT:SLEW:TRIG