Agilent Technologies 6814B Welding System User Manual


 
Language Dictionary - 3
81
PHASe:MODE
Phase Selectable
This command determines how the output phase is controlled during a triggered output transient. The
choices are:
FIXed
The output phase is unaffected by a triggered output transient.
STEP
The output phase is programmed to the value set by PHASe:TRIGgered when a triggered
transient occurs.
PULSe
The output phase is changed to the value set by PHASe:TRIGgered for a duration
determined by the pulse commands.
LIST
The output phase is controlled by the phase list when a triggered transient occurs.
Command Syntax
[SOURce:]PHASe:MODE <mode>
Parameters
FIXed | STEP | PULSe | LIST
*RST Value
FIXed
Examples
PHAS:MODE LIST PHAS:MODE FIX
Query Syntax
[SOURce:]PHASe:MODE?
Returned Parameters
<CRD>
Related Commands
PHAS PHAS:TRIG
PHASe:TRIGgered
Phase Selectable
This command sets the output phase when a triggered step or pulse transient occurs. The phase of the
output voltage waveform is expressed relative to an internal reference. The phase angle is programmed in
degrees. Positive phase angles are used to program the leading phase, and negative phase angles are
used to program the lagging phase.
The PHASe command is not influenced by INSTrument:COUPle ALL. It applies only to the current output
phase selected by INSTrument:NSELect.
Command Syntax
[SOURce:]PHASe:TRIGgered <NRf+>
Parameters
–360 through +360 (degrees) | MAXimum | MINimum
*RST Value
triggered phase 1 = 0, triggered phase 2 = 240,
triggered phase 3 = 120
Examples
PHAS:TRIG 90 PHAS:TRIG MAX
Query Syntax
[SOURce:]PHASe:TRIGgered?
Returned Parameters
<NR3>
Related Commands
PHAS:MODE PHASE