Dukane 403570-01 Welder User Manual


 
Dukane Manual Part No. 403-570-01
Page 99
Appendix A
1
2
3
7
11
15
6
10
14
16
Slide Kit Connector
The slide kit interface is a round 16–pin connector
located directly to the right of the base interface
connector on the rear of the thruster. The Dual Servo
Spin Welder is prewired to accept a Dukane slide kit
without any modication or reprogramming of the
press. The connector is shown in Figure 3–8. The
connector will interface to a Left/Right or an In/Out
slide kit, and provides activation signals to extend and
retract the slide table as well as readouts of the table
position switches. It also provides an input for a signal
from a part presence sensor. The pin numbers for the
connector are shown in Figure A–3. The pin assignments
and signal descriptions are given in Table A-III.
Figure A–3 Slide Kit Connector
Table A-III Pin Assignments and Signal Description for the Slide Kit Connector
Pin Signal Description Function
1 Ground Ground connection
2 (No Connection) ---
3 Slide Out Sense (Left) Input Activate when slide is in Out (Left) position
4 Output Common Output common connection
5 Top-of-Stroke Output (Closed at TOS) ON when press is at Top-of-Stroke position
6 Slide In Sense (Right) Input Activate when slide is in In (Right) position
7 In/Out Slide Identicaiton Input Activate to designate connected slide as In/Out type (ensure Pin 8
is disconnected)
8 Left/Right Slide Identicaiton Input Activate to designate connected slide as Left/Right type (ensure Pin
7 is disconnected)
9 Part Presence Sensor Input Activate when part presence is sensed
10 Ground Ground connection
11 Slide In (Right) Output ON when welder calls for slide to move to the In (Right) position
12 Slide Home Status Output ON when slide is in Home position
NOTE: home slide position is Out (Left)
13 Ready Status Output ON when welder is ready to initiate a weld cycle
14 Slide Out (Left) Output ON when welder calls for slide to move to the Out (Left) Position
15 Ground Ground connection
16 +24V DC Switched
(Power OFF when Abort switch pushed)
+24V DC switched connection