Dukane Manual Part No. 403-570-01
Page 47
Section 5 - Touch Screen Menus
Screen Parameter Name Min.Value Max.Value Resolution Units
SETUP>
PRE-WELD
TOOL Inertia
0
3000 (SVT012VR)
780 (SVT032VR)
160 (SVT042VR)
1 kg* cm²
TOOL Weight 0 25.0 0.1 kg
SPIN Decel. 25 200 1 %
TOP OF STROKE Position 0 140.00 0.01 mm
TRIGGER Position 1.00 140.00 0.01 mm
Part Pickup Position 1.00 140.00 0.01 mm
Part Pickup Thrust 1 100 1 %
Part Pickup Timeout 1 60 1 sec.
Pre-Spin Orientation 0 359.9 0.1 deg.
SETUP>
WELD
Weld Time/
Weld Rotations/
Weld Distance (Vertical) /
Energy
0.01 50000 0.01
sec./
rev./
mm/
Joules
VERT. Speed .01 100.00 0.01 mm/s
SPIN RPM
5
750 (SVT012VR)
3000 (SVT032VR)
4000 (SVT042VR)
1 RPM
Weld Orientation 0 359.9 0.1 deg.
Trigger Torque
1
100
1 %
Torque Trigger Timeout 1 60 1 sec.
Constant Torque 1 100 1 %
Constant Torque Timeout 1 60 1 sec.
SETUP>
POST-WELD
Hold Speed .01 100 0.01 mm/s
Hold Move Time/
Hold Collapse
0 140.00 0.01
sec./
mm
Hold Dwell Time 0 100.00 0.01 sec.
Hold Constant Thrust 1 100 1 %
TOOLS>
SYSTEM
SETUP
Home Offset 0 359.9 0.1 deg
Parameter Value Range
The minimum and maximum values of the welding
parameters are listed in Table 5-I.
Table 5–I Welding Parameters