A_39 Jog stop mode 00 00 00
A_41 Torque boost method selection 00 00 00
A_42 Manual torque boost value 11 11 11
A_43 Manual torque boost frequency
adjustment
10.0 10.0 10.0
A_44 V/f characteristic curve selection 00 00 00
A_45 V/f gain setting 100 100 100
A_51 DC braking enable 00 00 00
A_52 DC braking frequency setting 0.5 0.5 0.5
A_53 DC braking wait time 0.0 0.0 0.0
A_54 DC braking force during deceler-
ation
000
A_55 DC braking time during decelera-
tion
0.0 0.0 0.0
A_61 Frequency upper limit setting 0.0 0.0 0.0
A_62 Frequency lower limit setting 0.0 0.0 0.0
A_63,
A_65,
A_67
Jump (center) frequency setting 0.0 0.0 0.0
A_64,
A_66,
A_68
Jump (hysteresis) frequency
width setting
0.5 0.5 0.5
A_71 PID Enable 00 00 00
A_72 PID proportional gain 1.0 1.0 1.0
A_73 PID integral time constant 1.0 1.0 1.0
A_74 PID derivative gain 0.0 0.0 0.0
A_75 PV scale conversion 1.00 1.00 1.00
A_76 PV source setting 00 00 00
A_81 AVR function select 02 00 02
A_82 AVR voltage select 230/400 230/460 200/400
A_92 Second acceleration time setting 15.0 15.0 15.0
A_93 Second deceleration time setting 15.0 15.0 15.0
A_94 Select method to switch to second
accel/decel profile
00 00 00
“A” Group Parameters Default Setting
User
Setting
Func.
Code
Name
-FE