This is a typical DC output voltage
waveform generated from a properly
operating machine. Note that each
vertical division represents 20 volts
and that each horizontal division rep-
resents 1.0 milliseconds in time.
Note: Scope probes connected at
machine output terminals: (+)
probe to electrode, (-) probe to
work.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep..1.0 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (MAX TAP “G”)
0 volts
1.0 ms
20.0V