107A
106C
106B
Output
Contactor
FIGURE F.23 – OUTPUT CONTACTOR LEADS
OUTPUT CONTACTOR REMOVAL AND REPLACEMENT PROCEDURE
(continued)
PROCEDURE
1. Using a 5/16” nutdriver, remove the three
screws securing the tool tray.
2. Locate the output contactor. See Figure F.23.
3. Using a 7/16” wrench, label and remove the two
thick black leads at the top of the output con-
tactor. Note lead and washer placement for
reassembly.
4. Remove lead 107A and note lead placement.
See Figure F.23.
5. Remove leads 106B and 106C. See Figure
F.23.
6. Using a 7/16” wrench, remove the three mount-
ing bolts from the output contactor. Note wash-
er positions for replacement. See Figure F.24.
7. Replace output contactor.
8. Using a 7/16” wrench, mount the new output
contactor in its proper location.
9. Reconnect leads 106B, 106C, & 107A to their
proper terminals. See Wiring Diagram.
10. Reconnect the two thick black leads previously
removed from the top of the output contactor.
11. Replace the tool tray using a 5/16” nutdriver.
TROUBLESHOOTING AND REPAIR
F-50 F-50
Power MIG® 215XT
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC