Lincoln Electric SVM172-A Welding System User Manual


 
POWER FEED 10M SINGLE/DUAL
OPERATION
B-10 B-10
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
SETUP FEATURES MENU
The Setup Menu gives access to the set-up configuration.
Stored in the setup configuration are user parameters that
generally need to be set only at installation. The parameters
are grouped as follows:
P.1 through P.99 Unsecured Parameters (always
adjustable)
P.101 through P.199 Diagnostic Parameters (always
read only)
• P.501 through P.599 Secured Parameters (accessible
only though a p.c. or palm application.)
To access the setup menu, press the right and left buttons of
the MSP4 panel simultaneously. Note that the setup menu
cannot be accessed if the system is welding, or if there is a
fault (The status LED is not solid green).
Change the value of the blinking parameter rotating the SET
knob.
To exit the setup menu at any time, press the right and left
buttons of the MSP4 panel simultaneously. Alternately, 1
minute of inactivity will also exit the setup menu.
The following list includes all possible parameters in
ArcLink equipment. Not all of the parameters listed may
appear for your system. Refer to the (TABLE B.1) for
active parameters.
LIMIT SETTING
The MSP4 can be optionally configured to limit the operator’s
range of control of any weld parameter (weld WFS, arc con-
trol, etc.). Limits are only available with the Dual
Procedure/Memory Panel.
MACHINE SETUP/USER PREFERENCES
The MSP4 can be used to configure and troubleshoot the
machine.
ACCESSING THE MACHINE SETUP MENU
To access the Machine Setup menu, press both MSP4 push
buttons simultaneously.
The MSP4 7-segment display will
display the first user preference, "P.0", and the SETUP LED
will illuminate.
Pressing the left MSP4 pushbutton will exit the entire
Machine Setup menu while in the P.0 user preference.
• Turning the MSP4 encoder knob will select other available
User Preferences.
To exit the User Preference Menu, either rotate the MSP4
encoder until P.0 is displayed and press the left MSP4
pushbutton or press both MSP4 push buttons simultane-
ously at any time.
PARAMETER
P.0
P.1
P. 2
P. 3
P. 4
P. 5
P. 6
P. 7
P.8
P. 9
P. 11
P.12
P.13
P.80
P.99
DESCRIPTION
Exit set-up menu
WFS Units
Arc Display Mode
Display Power
Trigger Memory Recall
Trigger Procedure Change
Stall Factor Adjustment
Gun Offset Adjustment
TIG Gas Control
Crater Delay
Set Timers
Travel Options
Adjust Arc Force
Sense From Studs
Show Test Modes
View Diagnostics
View Event Logs
View Fatal Logs
View Software Version
View Hardware Version
View Welding Software
View Ethernet IP Address
View Power Source Type
P.100
P.101
P.102
P.103
P.104
P.105
P.106
P.107
Unsecured Parameters
Diagnostic Parameters
PF*-10M (All Models)
PF*-15M
PF*-10A
TABLE B.1
* PF= POWER FEED