OPERATION
1. Input Voltage warning light green LED - Indicates
that the machine is on and input voltage is within
acceptable range.
2. Thermal Shutdown Light (yellow LED) - Indicates
thermal over load or output disabled for incorrect
supply voltage.
•With the "Yellow LED" on, and an alarm code blink-
ing on "Digital Display Item 6" (see Troubleshooting
Section E, "Possible electrical problems"), the
machine will not supply power at the output.
• If over-heating occurs, the "Yellow LED" will stay on
until the machine has sufficiently cooled. Leave the
power source on to allow the fan to cool the unit.
3. Pulse On/OFF push button - CONSTANT current
- PULSED current
4. Setup/Parameter Select push button -
“Setup/Parameter" push button has three (3) differ-
ent functions:
Accesses Welding Parameter. Repeatedly pressing
the Parameter button will step through the Welding
Parameter waveform lights on the front panel.
Parameters which can be changed.
Start Current
Upslope
Weld Current (Peak Current)
Pulse Frequency
% on Time
Background Current
Downslope
Finish Current
Postflow sec.
There is a LED for each welding parameter. When
lit, it has confirmed the mode or selection chosen.
Accesses the "AC Frequency" and "AC Balance"
by pressing and holding the Parameter button for
three (3) seconds.
Accesses the "Set Up Menu". See Set Up Menu
section.
CONTROLS AND SETTINGS
All operator controls and adjustments are located on
the case front of the V205-T machine. Refer to Figure
B.2 and the corresponding explanations.
2. Thermal / Device Warning Light Yellow LED
6. Digital Display
1. Input Voltage warning Light Green LED
5. Output/Parameter Adjust Knob
4. Setup/Parameter Select Button
9. Welding Process (MODE) Button
7. Local/Remote Button
3. Pulse On/Off Button
8.Trigger Selection Button
10. Electrode Connection (Negative)
11. Remote Control Connector
12. Electrode Connection (Positive)
13. Welding Parameter Drawing
sec
sec
LOCAL
1
9
10
11
12
13
8
7
6
5
4
3
2
FIGURE B.2