Lincoln Electric V205-T Welder User Manual


 
B-12 B-12
V205-T AC/DC
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
OPERATION
DC TIG WELDING QUICK START UP
ELECTRIC SHOCK can kill.
• Have an electrician install and
service this equipment.
• Turn the input power off at the fuse box, dis-
connect or unplug supply lines and allow
machine to sit for five minutes minimum to
allow the power capacitors to discharge
before working inside this equipment.
• Do not touch electrically hot parts.
------------------------------------------------------------------------
Connect up the shielding gas – typically argon – using
an appropriate regulator. Connect foot amptrol, torch
and work lead to power source.
With the Work cable connected to a properly grounded
work piece, turn the power source on.
To change to DC TIG Welding:
• Press Mode button to select "DC TIG."
• Press Trigger Mode button and set to 2-step.
Press Local / Remote Mode button and set for
Remote.
• Pulsing parameters selected by Parameter button,
and changed using Output Control.
Set the maximum output current desired using the
Output Control.
Initiate the arc by closing the Foot Amptrol’s arc start
switch. The Amptrol will control the output current from
10 amps to current level set by output control.
To change the Post Flow time, repeatedly push the
Parameter button until the Post Flow indicator light is
on. Adjust the Output control to the desired Post Flow
time as indicated on digital display.
To change from High Frequency to Lift Start, turn
power source off. Press and hold the Parameter button
while the power source is turned on. A “0” in the center
of the digital display indicates the Set Up Menu is now
active. Rotate the Output Control until # 8 is displayed.
Press the Parameter button again and rotate the
Output Control until “1” is displayed. Press the
Parameter button to accept this setting. Rotate the
Output Control until “0” is displayed. Press the para-
meter button to exit the Set Up Menu.
WARNING