Lincoln Electric V205-T Welder User Manual


 
TROUBLESHOOTING AND REPAIR
OUTPUT FILTER BOARD TEST (continued)
F-36 F-36
V205-T AC/DC
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TEST PROCEDURE
1. Remove input power to the V205-T machine.
2. Using a phillips head screwdriver, remove the
case wraparound cover.
3. Perform the Capacitor Discharge Procedure
detailed earlier in this section.
4. Locate the Output Filter board and associated
plugs . Do not remove plugs from the
board. See Figure F.16.
5. Carefully apply the correct input voltage to the
V205-T and check for the correct secondary
voltages per Table F.12.
FIGURE F.16 OUTPUT FILTER BOARD LOCATION
Output Filter Board