Honeywell N431X Stud Sensor User Manual


 
6 - 38
If you scan the Single Code Output code, when the engine sees the cou-
pon code and Code 128 code in a single scan, it transmits the data as one
extended bar code.
Default = Multiple Code Output.
UPC-A Number System 4 Addenda Required
This setting programs the engine to require a coupon code only on UPC-A
bar codes that begin with a “4.” The following settings can be programmed:
Require Coupon Code: All UPC-A bar codes that begin with a “4” must
have a coupon code. The UPC-A bar code with the coupon code is then
transmitted as a single, concatenated bar code. If a coupon code is not
found within the Addenda Timeout period, the UPC-A bar code is dis-
carded.
Don’t Require Coupon Code: If you have selected Require Coupon
Code, and you want to disable this feature, scan Don’t Require Coupon
Code. UPC-A bar codes are transmitted, depending on the setting you are
using for UPC-A/EAN-13 with Extended Coupon Code.
Default = Don’t Require Coupon Code.
UPC-A Number System 5 Addenda Required
This setting programs the engine to require any combination of a coupon
code, a 2 digit addenda, or a 5 digit addenda on UPC-A bar codes that
begin with a “5.” The following settings can be programmed:
Require Coupon Code/Addenda: All UPC-A bar codes that begin with a
“5” must have a coupon code, a 2 digit addenda, a 5 digit addenda, or a
combination of these addenda. The UPC-A bar code with the coupon code
and/or addenda is then transmitted as a single, concatenated bar code. If
a coupon code and/or required addenda is not found within the Addenda
Timeout period, the UPC-A bar code is discarded.
Single Code Output
* Multiple Code Output
Require Coupon Code
* Don’t Require Coupon Code