WELDING CAPABILITY
The CV-400 has the following duty cycle ratings. If the
duty cycle is exceeded, a thermal protector will shut off
the machine output until it cools to normal operating
temperature. The amber thermal protection indicator
light will turn on until the machine cools.
*Based on a 10 minute time period. For example, a 60% duty cycle
means 6 minutes on and 4 minutes off.
LIMITATIONS
The IDEALARC CV-400 has no provisions for parallel-
ing. It should not be used outdoors without rain shel-
tering.
OPERATION
B-4 B-4
IDEALARC CV-400
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Duty Cycle* Amps Volts
100% 400 36
60% 450 38
50% 500 40