Lincoln Electric SVM136-A Welder User Manual


 
ACCESSORIES
C-5 C-5
IDEALARC CV-400
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
5. Extend wire feeder control cable lead #21 so it can
be connected directly to the work piece.
a. Make a bolted connection using AWG #14 or larg-
er insulated wire. Tape the bolted connection with
insulating tape.
b. An S-16586- X remote voltage sensing work lead
is available for this purpose.
c. Keep the #21 lead electrically separate from the
work cable circuit and connection.
d. Tape the #21 lead to the work cable for ease of
use.
6. Connect NA-5 wire feeder control jumpers on
Voltage Control Board. See the NA-5 operator's
manual.
NOTE: For proper NA-5 operation, the electrode
cables must be secured under the clamp bar on the
left side of the NA-5 Control Box.
NOTE: The connection diagram shown in
Figure C.3
shows the electrode connected for positive polarity. To
change polarity:
a. Set the CV-400 POWER toggle switch to the OFF (0)
position.
b. Move the electrode cable to the negative (-) output
terminal.
c. Move the work cable to the positive (+) output termi-
nal.
d. Set the VOLTMETER toggle switch to negative (-).
e. See
NA-5
manual for changing welding polarity.