Lincoln Electric SVM136-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-47 F-47
IDEALARC CV-400
REMOVAL OF LIFT BAIL
1. Remove the main input supply power to the
machine.
2. With the 5/16” nut driver, remove the case
top and sides.
3. Remove the two fiber baffles from the left
and right sides of the lift bail adjacent to the
main transformer. See Figure F.25.
4. Remove the two leads (#220 and #204)
from resistor R2 (7.5 ohms, 100 watts).
5. Remove the positive capacitor strap from
the output shunt.
6. Remove the negative capacitor strap from
the negative rectifier plate.
7. Remove the sheet metal screw that holds
the capacitor bank assembly to the case
back. (This should enable the capacitor
bank to be removed with the lift bail assem-
bly.)
8. Using the 9/16” socket wrench, remove the
four bolts (left and right) mounting the lift bail
to the transformer top and bottom irons.
9. Using the 9/16” socket wrench, remove the
four bolts, flat washers, and lock washers
mounting the lift bail assembly to the base of
the machine.
The transformer and choke assembly is now
loose and free to slide or “tip” on the base of the
machine.
10. Remove the lift bail by lifting straight up and
clear from the machine.
MAIN TRANSFORMER REMOVAL & REPLACEMENT (continued)
WARNING
FIGURE F.25 – LIFT BAIL REMOVAL