Lincoln Electric SVM136-A Welder User Manual


 
CONNECTING THE LN-8 OR LN-9 TO THE
IDEALARC CV-400
1. Set the CV-400 POWER toggle switch to the OFF (0)
position.
2. Disconnect main AC input power to the CV-400.
3. Connect the wire feeder control cable leads to the
CV-400 terminal strip as shown in Figure C.5.
4. Connect the wire feeder control cable ground lead
to the frame terminal marked .
5. Extend wire feeder control cable lead #21 so it can
be connected directly to the work piece.
a. Make a bolted connection using AWG #14 or
larger insulated wire. Tape the bolted connection
with insulating tape.
b. An S-16586- X remote voltage sensing work lead
is available for this purpose.
c. Keep the #21 lead electrically separate from the
work cable circuit and connection.
d. Tape the #21 lead to the work cable for ease of
use.
NOTE: Using the extended #21 lead eliminates the
need to use the LN-9's remote work lead accesso-
ry, which has a direct work lead jack.
6. Connect the LN-9 wire feeder control jumpers on
the Voltage Control board. See LN-9 operator's
manual.
NOTE: The connection diagram shown in Figure C.5
shows the electrode connected for positive polarity.
To change polarity:
a. Set the CV-400 POWER toggle switch to the OFF
(0) position.
b. Move the electrode cable to the negative (-) out-
put terminal.
c. Move the work cable to the positive (+) output
terminal.
d. Set the VOLTMETER toggle switch on power
source to negative (-).
e. Set the voltmeter toggle switch on feeder (if
equipped) to match electrode polarity.
ACCESSORIES
C-7 C-7
IDEALARC CV-400
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
FIGURE C.5
LN-8 OR LN-9 WIRE FEEDER CONNECTION TO THE IDEALARC CV-400
+
-