Lincoln Electric SVM158-A Welding System User Manual


 
TROUBLESHOOTING AND REPAIR
RETEST AFTER REPAIR
F-93 F-93
V350-PRO
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Required Action
Expected Results
Rt. displayLft.display
Test
Steps
13
14
15
16
17
18
19
20
21
22
Turn the Advanced Process Panel left encoder clockwise
until the value displayed on the Advanced Process Panel
lower left display equals 100. Note that this should require
exactly one revolution of the encoder knob.
Turn the Advanced Process Panel left encoder counter-
clockwise until the value displayed on the Advanced
Process Panel lower left display equals zero. Note that
this should require exactly one revolution of the encoder
knob.
Turn the Advanced Process Panel right encoder clockwise
until the value displayed on the Advanced Process Panel
lower left display equals 100. Note that this should require
exactly one revolution of the encoder knob.
Turn the Advanced Process Panel right encoder counter-
clockwise until the value displayed on the Advanced
Process Panel lower left display equals zero. Note that
this should require exactly one revolution of the encoder
knob.
Press and hold the Advanced Process Panel Memory but-
ton until the right display changes to on.
Release the Advanced Process Panel Memory button.
Press and hold the Advanced Process Panel Select button.
Release the Advanced Process Panel Select button.
Verify that the Advanced Process Panel upper left display
contains the following pattern and that the brightness of
the characters is uniform:
“0123456789ABCDEF”
Press and release the Advanced Process Panel Memory
button to advance to the next step.
Verify that the Advanced Process Panel lower left display
contains the following pattern and that the brightness of
the characters is uniform:
“0123456789ABCDEF”
Press and release the Advanced Process Panel Memory
button to advance to the next step.
LEnc
LEnc
rEnc
rEnc
EorY
EorY
rSEL
rSEL
dISP
dISP
=100
=0
=100
=0
oFF
on
oFF
on
1
2
NOTE: If an Advanced Process Panel is not installed in the machine, skip steps 13-24