Lincoln Electric SVM158-A Welding System User Manual


 
V350-PRO
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
SERVICE FACILITY
CORRECTIVE
ACTION
CORRECTIVE
ACTION
DESCRIPTION/
DEFINITION
39
43
44
Electrical "glitch" on the
primary over current fault
detector circuit.
Capacitor banks "A"
(lower) and "B"(upper)
are not balanced.
The machine has
detected a fault in the
central processing unit
(CPU).
Possibly caused by an
external electrical
"noise" or signal level.
Make sure the V350-Pro
is grounded correctly.
The machine is self
clearing when
condition ceases.
Make sure the recon-
nect switches are con-
figured for the input
voltage being applied to
the machine. The
machine is self-clearing
when
condition ceases.
Make sure the V350-Pro
is grounded correctly.
The machine is self
clearing when
condition ceases.
Perform the Main Switch
Board Test.
Perform the Power
Board Test.
There may be a problem
with the primary current
sensors (CT) located on
the main switch board.
See the wiring diagram.
The control board may
be faulty.
There may be a problem
with the V/F signals from
the main switch board to
the control board.
Perform the Main Switch
Board Test.
The capacitor(s) may be
faulty. Check and
replace if necessary.
Perform the Power
Board Test.
The control board or
associated wiring may be
faulty. See the wiring
diagram.
TROUBLESHOOTING & REPAIR
F-12 F-12
FAULT CODES
NOTE: If more than one fault message is being displayed, perform all the checks for the faults
before replacing the printed circuit board