Lincoln Electric SVM189-B Welder User Manual


 
INSTALLATION
A-2 A-2
COMPACT WIRE WELDERS
TECHNICAL SPECIFICATIONS
180 Amp units
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency Input Current
230 V 60 Hz 20 Amps @ rated output
208 V 60 Hz 20 Amps @ rated output
Voltage/Duty
Cycle Current Voltage at Rated Amperes
230 V 30% 130 Amps 20
208 V 30% 130 Amps 17
Welding Current Range Open Circuit Voltage Wire Speed Range
30-180 Amps 34 V 50 - 500 in/min.
(1.3 - 12.7 m/min.)
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height Width Depth Weight
14.0 in 10.15 in 18.6 in 66 Ibs
357 mm 258 mm 472 mm 30 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.
TECHNICAL SPECIFICATIONS 140 Amp units
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency Input Current
120 V / 60 Hz 20 Amps @ rated output
Duty
Cycle Current Voltage at Rated Amperes
20% Duty Cycle 90 Amps 19.5
Welding Current Range Open Circuit Voltage Wire Speed Range
30-140 Amps 33 V 50 - 500 in/min.
(1.3 - 12.7 m/min.)
Input Voltage/Frequency Fuse or Breaker Size
1,2
Input Amps Power Cord Extension Cord
120 V 60 Hz 20 Amp 20 15 Amp, 125 V,
3 Conductor # 12 AWG
Three Prong Plug (4mm
2
) or Larger
(NEMA Type 5-15P) up to 50 ft.(15.2m)
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height Width Depth Weight
14.0 in 10.15 in 18.6 in 58 Ibs
357 mm 258 mm 472 mm 26.3 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.
Input Voltage/Frequency Fuse or Breaker Size
1
Input Amps Power Cord
230 V 60 Hz 40 Amp Super Lag 20 50 Amp, 250 V,
Three Prong Plug
(NEMA Type 6-50P)