Lincoln Electric SVM 113-A Welder User Manual


 
TABLE D.2 – ENGINE MAINTENANCE PARTS
Part Part Number
OIL FILTER NONE
SPARK PLUG (STANDARD) B&S 492167
SPARK PLUG (RESISTOR) B&S 491055
CHAMPION RC12YC
AIR CLEANER CARTRIDGE B&S 710266
(CAN BE CLEANED AND REUSED)
AIR PRE-CLEANER B&S 710268
(AS NEEDED) (CAN BE CLEANED AND REUSED)
MAINTENANCE
D-5 D-5
WELDANPOWER 125
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
WELDER/GENERATOR MAINTENANCE
STORAGE: Store the WELDANPOWER 125 in clean,
dry, protected areas.
CLEANING: Blow out the generator and controls peri-
odically with low pressure air. Do this at least once a
week in particularly dirty areas.
BRUSH REMOVAL AND REPLACEMENT: See
Figure D.6. It’s normal for the brushes and slip rings
to wear and darken slightly. Inspect the brushes
when a generator overhaul is necessary. Remove the
brushes and clean the slip rings with fine grit sand-
paper.
Do not attempt to polish slip rings while the engine is
running.
To reinstall the brushes, press them upward and slide
a cable tie or wooden stick through the brush
holder tabs. Install the brush holder into the bearing
end bracket and secure with the screws previously
removed. Remove the cable tie or wooden stick and
the brushes will seat onto the slip rings.
RECEPTACLES: Keep the electrical receptacles in
good condition. Remove any dirt, oil, or other debris
from their surfaces and holes.
CABLE CONNECTIONS: Check the welding cable
connections at the weld output terminals often. Be
sure that the connections are always firm.
CAUTION
1
3
5
6
2
4
FIGURE D.6 – BRUSH REMOVAL AND REPLACEMENT
1. GENERATOR END BRACKET
2. BRUSH HOLDER ASSEMBLY
3. COVER
4. SCREWS (2)
5. BRUSHES
6. CABLE TIE