Lincoln Electric SVM 113-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-32 F-32
WELDANPOWER 125
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling ............................DC
Trigger .........................Internal
CH1
0 volts
5 ms
50 volts
This is the typical AC output voltage
generated from a properly operating
machine. Note that each vertical
division represents 50 volts and that
each horizontal division represents 5
milliseconds in time.
Note: Scope probes connected at
machine 115 VAC receptacle.
1 Period = 16.2 ms @ 3700 rpm
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115 VAC SUPPLY)
HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM