Lincoln Electric SVM 113-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-59 F-59
WELDANPOWER 125
RETEST AFTER REPAIR
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine’s electrical characteristics.
OR
• If you repair or replace any electrical components.
ENGINE OUTPUT
No Load RPM Load RPM
Maximum Speed 3800 3500
Minimum Speed 3700 3300
WELDER/GENERATOR OUTPUT
1
Output Control Field Volts Field Amps Open Circuit Load Volts Load Amps
Volts RMS
Maximum 40 - 47 4.0 - 6.4 75 - 82 22 - 28 125 - 135
Minimum 70 - 78 23 - 27 40 - 55
AUXILIARY POWER RECEPTACLE OUTPUT
1
230 Volt Receptacle 115 Volt Receptacle
2
Output Open Circuit Load Volts Load Amps Open Circuit Load Volts Load Amps
Control Volts Volts
Maximum 240 - 260 208 - 234 20.2 - 22.0 120 - 130 104 - 117 20.2 - 22.0
1
Current Control Dial set at MAXIMUM.
2
Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.