Sterling D48160s Saw User Manual


 
42
SETTINGS AND ADJUSTMENTS
SECTION 4-7
Adjusting or Replacing Bed Knives
MEASURE THE KNIFE GAP
If you are changing the rotor knives, do that now,
otherwise, continue with this procedure.
Use brass shim stock to set the knife gap to the cutting
clearance of 0.006 in. to 0.008 in. (0.15 mm to 0.20
mm).
Remove the rotor-locating pin.
Rotate the rotor backward, by hand, and measure the
gap between it and the bed knife at the point of shear.
You can work on each half of the bed knife
independent of the other half but keep them in step
with each other by working from side-to-side.
SET THE DOWNSTROKE KNIFE SHIELD
Position the knife-shield so that it sets back from the
bed knife-edge about 1/32 in. for film and 1/16 in. for
thicker materials. Use a plastic or leather mallet, if
necessary, to tap the shield or knife-
The upstroke knife clamp does not need this
adjustment.
Carefully adjust the bed knife clearance to its final
setting and snug down the mounting screws with a 30
mm socket wrench.
CHECK THE KNIFE GAP
Snug the screws down in stages keeping them about even as you progressively tighten them.
Recheck the knife gap after snugging down the mounting screws.
After setting up to one rotor knife (usually the highest knife), rotate the remaining knives slowly
by the bed knife and quickly verify the knife gap.