Sterling D48160s Saw User Manual


 
71
SETTINGS AND ADJUSTMENTS
SECTION 4-35
Adjustable rotor knives
KNIFE LENGTH SETTING-INSPECTION
Check with a .0015 feeler gauge to ensure that cutting edge of the knife PHOTO
is snug against the front setting block. This should be consistent along Knife in fixture
the entire block length.
If the fit is proper then the knife is at it’s proper operational length.
Loosen the front setting block screw and remove the knife.
ADJUSTABLE ROTOR KNIFE INSTALLATION
Set the knife on the rotor knife seat. The head of the rear adjusting
screws should contact the rotor mounted locaters. PHOTO
Knife on rotor
Check with a .0015 feeler gauge to ensure that the adjusting screws
are snug against the locaters.
The rotor mounted locaters are specifically sized to provide
the proper knife setting location. If replacement is required use only
factory supplied locaters.
To finalize the rotor knife installation, see the rotor knife installation
instructions stated previously in this manual