CHANGING VOLTAGE
See Figures2-4.
Your radial saw has been set up atthe factoryto
operate efficientlyon a 120V AC single voltagecircuit.
However, if heavy duty operation is required,the
circuits are overloaded, or the circuitis lowvoltage,
have a qualified electricianchange the voltageon the
main power system to a 240V AC voltagecircuit.
,_ WARNING: The controlcut device is set up for
a 120V AC singlevoltage circuit.Do not modify
the control cut cord. Identifythe controlcut
cordand tie it back out of the way.
• Correctly identifythe controlcut cord, unplugit,
and set itaside.
• Unplug the main power cord.
• Remove the blade followingthe procedure in the
Assembly section.
• Remove the pan head screw above the blade
arbor on the motorcover. Liftmotorcover to
expose switch. See Figure2.
• Use a small screwdriverto slide the dual voltage
switch tothe 240V position.See Figures 3 and 4.
• Reinstall motorcover.
• Replace the 120V plugon the main cordwith a UL
listed 240V, 15 amp, 3-prong plug.
• Follow the instructionsprovidedwith the UL listed
plug.
• Plug the cord intoa 240V, 15 amp, 3-blade recep-
tacle. Make sure the receptacle isconnectedto a
240V AC power supplythrougha 240V branch
circuitthat has a 15 amp fuse or circuitbreaker.
Note: No adapter isavailable for this type of plugor
receptacle.
MOTORCOVER
PANHEADSCREW
LIFTMOTORCOVERTOEXPOSESWITCH
SLIDEASSHOWNFORSINGLEVOLTAGECIRCUITS
SWITCHSHOWNIN110-120VOLTPOSmON
Fig. 3
UFTMOTORCOVERTOEXPOSESWITCH
SLIDEASSHOWNFORDUALVOLTAGECIRCUITS
SWITCHSHOWNIN220-240VOLTPosmoN
Fig. 4
O
BLADEARBOR Fig. 2
9 (RIIR'SHnN"RADIALSAW315.220381