Delta Electronics 230V Series Welder User Manual


 
Chapter 5 Parameters|VFD-S Series
5-16 Revision August 2006, SE08, SW V2.61
Output Signal when Frequency Attained
Applications Purpose Functions
Related
Parameters
General application
Provide a signal for
running status
When the output frequency is at the
desired frequency (by frequency
command), a signal is given for
external system or control wiring
(frequency attained).
3-05~3-06
3-04
3-10
Output Signal for Base Block
Applications Purpose Functions
Related
Parameters
General application
Provide a signal for
running status
When executing Base Block, a signal
is given for external system or control
wiring.
3-05~3-06
Overheat Warning for Heat Sink
Applications Purpose Functions
Related
Parameters
General application For safety
When heat sink is overheated, it will
send a signal for external system or
control wiring.
3-05~3-06
Multi-function Analog Output
Applications Purpose Functions
Related
Parameters
General application
Display running
status
The value of frequency, output
current/voltage can be read by
connecting a frequency meter or
voltage/current meter.
3-05