Lincoln Electric SVM204-A Welder User Manual


 
OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
(Continued)
8. Observe the oil level indicator
light while cranking the engine.
If the light is blinking while
cranking the engine, the oil level
may be low, or the oil level
system may be faulty. Contact
the engine manufacturer.
Reconnect P4/J4 to shut the
engine down.
Attempt to start the engine
using the recoil starter; if the
engine starts, check lead #212
for faulty insulation. If lead
#212 is good, replace the PC
board.
If the engine fails to start, have
the engine and oil level system
checked by a qualified engine
service technician.
The engine will not shut down.
1. Place the engine switch in the
“stop” position and check for
battery voltage at the PC board
pin J3-10. (lead #211) If
voltage is present, the switch is
defective.
2. Locate and ground the
brown/white lead from the
engine ignition magneto. If the
engine still will not shut down,
the engine ignition magneto
may be defective. Contact a
qualified engine technician.
3. If the engine shuts down when
the brown/white lead is
grounded, check wiring and
connections at leads #212,
GND-I, GND-J, and the brown
leads between connector J4/P4
and the engine ignition
magneto. If these leads and
connections are good, replace
the PC board.
TROUBLESHOOTING AND REPAIR
F-5 F-5
OUTBACK® 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC