TEST DESCRIPTION
This test determines if the stator is producing the correct voltage from each of the wind-
ings. This test should be performed if rotor voltage is normal but one or more of the out-
put voltage readings are incorrect.
MATERIALS NEEDED
Miscellaneous hand tools
Wiring diagram
Multimeter
STATOR VOLTAGE TEST
TROUBLESHOOTING AND REPAIR