OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
The welding arc is “cold” or weld
performance is poor. Engine
operates normally and auxiliary
output is normal.
1. The weld boost circuit breaker
may have tripped. This circuit
breaker is a small button on the
bottom of the control box, not
far from the positive weld output
terminal.
2. Check the weld cables,
electrode holder, and work
clamp. Try welding with a
known good set of short,
adequately sized cables.
3. The battery may be low or
defective.
4. The welding electrode may be
wet or contaminated. Try using
a fresh dry welding electrode.
1. Perform the Engine RPM
adjustment procedure.
2. The brushes and slip rings
may be worn or faulty. Perform
the brush and slip ring
service procedure,
3. Perform the battery and
charging system tests.
4. Perform the weld boost
circuit tests.
TROUBLESHOOTING AND REPAIR
F-11 F-11