Lincoln Electric SVM204-A Welder User Manual


 
RETEST AFTER REPAIR
TROUBLESHOOTING AND REPAIR
F-53 F-53
OUTBACK® 185
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
PROCEDURE
No-load test values
High idle (No load) RPM: 3700-3800 RPM (61.7 – 63.3 Hz)
Low idle RPM: 2250-2500 RPM (37.5 – 41.7 Hz)
Weld terminal open Circuit Voltage (OCV):
Weld control at maximum: 70 – 80 VDC
Weld control at minimum: 45 – 60 VDC
Full load test values:
Weld output control set to maximum.
Output amps: 165 – 190, Volts: 21 – 27, RPM: 3300 – 3650
Weld output set to minimum:
Output amps: 40 – 55, Volts: 20 – 28
Auxiliary receptacles with weld output control set to maximum:
230 Volt receptacles:
Load amps: 22. – 25, Volts: 216 – 250 VAC
120 Volt receptacles:
Load amps: 20.2 – 24, Volts: 108 – 130 VAC
NOTE: Values shown above are for a machine that is at normal full load temperature. Readings will
likely be slightly higher if machine is cold.