Lincoln Electric V160-S Welder User Manual


 
INSTALLATION
AA-6 AA-6
V160-S & -T
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
• Ranger 250,305
• Commander 300, 400, & 500
Many engine drives do not meet these conditions (eg
Miller Bobcats, etc). Operation of the Invertec V160-T
is not recommended on engine drives not conforming
to these conditions. Such combinations may overvolt-
age the Invertec V160-T power source.
OUTPUT CONNECTIONS
ELECTRIC SHOCK can kill.
• Keep the electrode holder, TIG
torch and cables insulation in good
condition and in place.
• Do not touch electrically live parts or electrode
with skin or wet clothing.
• Insulate yourself from work and ground.
• Turn the input line Switch on the Invertec V160-
T “off” before connecting or disconnecting out-
put cables or other equipment.
-----------------------------------------------------------
OUTPUT CONNECTION FOR STICK
WELDING (FIGURE AA.2)
First determine the proper electrode polarity for the
electrode to be used. Consult the electrode data for
this information. Then connect the output cables to the
output terminals corresponding to this polarity. For
instance, for DC(+) welding, connect the electrode
cable (which is connected to the electrode holder) to
the “+” output terminal and the work cable (which is
connected to the work clamp) to the “-” output terminal.
Insert the connector with the key lining up with the key-
way, and rotate approximately 1/4 turn clockwise; until
the connection is snug. Do not over tighten.
OUTPUT AND GAS CONNECTION FOR
TIG WELDING (FIGURE AA.1)
This unit does not include a TIG torch, but one may be
purchased separately. The Lincoln PTA-9 (K1781-1 or
K1781-3 only with no gas valve) or PTA-17 (K1782-1
or K1782-3) are recommended for use with this
machine for this purpose; however, any similar TIG
torch can be used. To attach the Twist-Mate Plug to a
Lincoln Torch, slide the rubber boot onto the torch
cable (enlarge the boot opening if necessary), screw
the fitting on the torch cable into the brass connector
snugly and slide the boot back over the brass connec-
tor.
ADAPTEUR DE TIG
COMPOSÉ DE RETENUE
INITIALISATION DE PASSE-FILS
LE TIG INCENDIENT LE CABLE ÉLECTRIQUE AVEC LE GAZ FITING
WORK CLAMP
WORK CABLE
ELECTRODE
HOLDER
WARNING
The ground lead and TIG Torch Twist Mate®
Connector are supplied with the welder. To connect the
cables,turnthePowerSwitch “OFF”. Connect the torch
Twist Mate plug into the DC(-) Electrode/Gas Output
Receptacle on the front of the welder and turn it clock-
wise until tight.
WORK CABLE CONNECTION
Next, connect the work cable to the “+” output terminal
in the same way.
To minimize high frequency interference, refer to
Machine Grounding and High Frequency
Interference Protection section of this manual for the
proper procedure on grounding the work clamp and
work piece.
WORK CLAMP
WORK CABLE
TIG TORCH
GAS HOSE NOZZLE
FIGURE AA.1
FIGURE AA.2