Lincoln Electric V160-S Welder User Manual


 
TROUBLESHOOTING & REPAIR
F-38 F-38
V160-S & -T
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
RETEST AFTER REPAIR
If a failed test indicates that any mechanical part that could affect the machineʼs electri-
cal characteristics must be replaced or if any electrical components are repaired or
replaced, the machine must be retested and meet the following standards.
To test V160T on TIG mode set mode switch to LIFT TIG! “do not use HF TIG or dam-
age to measuring equipment will occur!!
To test HF on V160T attach tig torch, remote amptrol, and argon shielding gas.
Input Circuit
115V (20A Plug and Branch)
115V (30A Branch)
230V (30A Branch)
230V (30A Branch)
Maximum Open Circuit Voltage
48 Volts Max.
Duty Cycle
100%
35%
100%
Output Current Range
5-160 Amps
INPUT - SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Input Voltages / 50 /60 Hz.
115 V (20 A Plug and branch)
115 V (30 A branch)
230 V
Max. Input Current at rated Output
20 A
25 A
34 A
Output Amps
60 (Stick)
90 (TIG)
80 (Stick)
110 (TIG)
160 (Stick)
160 (TIG)
130 (Stick)
130 (TIG)
Output Volts
22.4
13.6
23.2
14.4
26.4
16.4
25.2
15.2
Type of Output
DC