Lincoln Electric V160-S Welder User Manual


 
TROUBLESHOOTING & REPAIR
F-23 F-23
V160-S & -T
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CHECK THE IGBT S FOR SHORTS
(AN OPEN STATUS NORMALLY IS EVIDENT)
CHECK FOR THERMAL
PROTECTION (~ 36 OHMS)
CHECK THE OUTPUT
DIODES FOR SHORTS
CHECK FOR (~ 1K OHMS)
CHECK THE DIODES FOR SHORTS
TEST PROCEDURE
1. Locate test points on inverter
board. See Figure F.12.
2. Check IGBT and diodes for shorts.
3. Check thermal protector for ~ 36
ohms.
4. Check lower left section as marked
for ~ 1K Ohms.
MAIN IGBT INVERTER BOARD V160-S/T
“WELDING LOGIC AND INVERTER” SECTION TEST
(continued)
FIGURE F.12 MAIN IGBT INVERTER BOARD LOCATION