GENERAL SPECIFICATIONS
Power Supply:
(1)
Power-Line Frequency:
Power Installation:
Power Consumption:
Operating Environment:
Storage Environment:
State Storage Memory:
Dimensions (W x H x D)
Bench Top:
Rack Mount:
Weight:
100V / 120V / 220V / 240V 10%
(switch selectable)
50 Hz to 60 Hz
10% and
400 Hz
10%. Automatically
sensed at power-on.
CAT II
50 VA peak (28 W average)
0
C to 55 C
80% Relative Humidity to 40
C
Indoor or sheltered location
-40
C to 70 C
Power-off state automatically
saved. Three (3) User-
Configurable Stored States,
Arbitrary waveforms stored
separately.
254.4 mm x 103.6 mm x 374 mm
212.6 mm x 88.5 mm x 348.3 mm
4 kg (8.8 lbs)
Safety Designed to:
EMC:
Vibration and Shock:
Acoustic Noise:
Warm-Up Time:
Warranty:
Remote Interface:
Programming Language:
Accessories Included:
EN61010, CSA1010, UL-1244
EN61326, 1:1997 + 1A:1998
MIL-T-28800E, Type III, Class 5
(data on file)
30 dBa
1 hour
3 years standard
IEEE-488 and RS-232 standard
SCPI-1993, IEEE-488.2
User’s Guide, Service Guide,
Quick Reference Card,
IntuiLink Arb software,
RS-232 cable, Test Report,
and power cord.
(1) For 400 Hz operation at 120 Vac, use the 100 Vac
line-voltage setting.
N10149
Chapter 1 Specifications
Agilent 33120A Function Generator