LG Electronics 32LY770M Saw User Manual


 
66
206-4271
* PCS150R and later Pro:Centric servers do not support HRC or IRC cable channel frequencies.
(Continued from previous page)
RF Conguration
a) Select/highlight the Media Type eld and press OK on the Installer Remote to display the
drop-down list of options. Then, use the Up/Down arrow keys to select RF.
Note: If the Media Type has already been set in the EZ-Manager Wizard, the specied value
will be reected in this eld.
b) For TVs in Pass-through Mode or FTG Mode via CPU, if the Data Channel is left at its
default value (AUTO), the TV’s Data Channel Auto Search feature will be enabled. See
Installer Menu item 119 DATA CHANNEL description on page 44 for further information.
To toggle between AUTO or MANUAL settings for the Data Channel, select/highlight the Data
Channel eld and press OK.
When the Data Channel eld is set to “MANUAL,” a data entry eld is available on the
screen, and you can specify the RF channel number that will be used by the Pro:Centric
server as its data channel. The Data Channel value can be set from 0 (disabled) to 135.*
Use the arrow keys on the Installer Remote to select the Data Channel data entry eld and
press OK. You can then use the number keys on the Installer Remote to direct enter the
Data Channel, or you can use the arrow keys to select the appropriate number(s) from the
pop-up virtual keyboard displayed at the bottom of the screen. When you are done, select
Enter from the virtual keyboard, and then press OK on the Installer Remote.
Note: If the Data Channel has already been set in the Installer Menu (Installer Menu item 119)
or in the EZ-Manager Wizard, the specied channel will appear in the Data Channel data entry
eld. If you change the Data Channel in this menu, Installer Menu item 119 will now show the
value you entered here.
IP Conguration
a) Select/highlight the Media Type eld and press OK on the Installer Remote to display the
drop-down list of options. Then, use the Up/Down arrow keys to select IP. IP Address and
Port Number elds will appear on the screen (in place of the Data Channel eld).
Note: If the Media Type has already been set in the EZ-Manager Wizard, the specied value
will be reected in this eld. Also, if the server IP address and port number have already
been set in the EZ-Manager Wizard, the specied data will be reected in the IP Address and
Port Number elds.
Note: Setting the Media Type to “IP” automatically sets item 119 DATA CHANNEL in the
Installer Menu to 253. You cannot alter this setting unless you revert Media Type to “RF.”
Also, it is not possible to direct enter “253” in the Installer Menu.
b) Enter the Pro:Centric server IP address and port number in the IP Address and Port Number
elds, respectively. The IP address must match the IPv4 multicast address and the port
number must match the port number that is set in the Pro:Centric server.
For each data entry eld: Use the arrow keys to select the eld and press OK. Then, you
can either use the number keys on the Installer Remote to direct enter data values or
use the arrow keys to select the appropriate number(s) from the pop-up virtual keyboard
displayed at the bottom of the screen. When you are done, select Enter from the virtual
keyboard, and then press OK on the Installer Remote.
IP Environment Setup (Cont.)
(Continued on next page)