Lincoln Electric SVM159-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-32 F-32
POWER WAVE 355/405
OUTPUT DIODE MODULES TEST (continued)
TEST PROCEDURE
1. Remove input power to the POWER WAVE
355/405.
2. Locate the output terminals on the front
panel of the machine. See Figure F.7.
3. Remove any output cables and load from the
output terminals.
4. Using the analog ohmmeter test for more
than 200 ohms resistance between positive
and negative output terminals. Positive test
lead to the positive terminal; Negative test
lead to the negative terminal. See Figure
F.8.
NOTE: The polarity of the test leads is most
important. If the test leads polarity is not cor-
rect, the test will have erroneous results.
FIGURE F.7 Machine Output Terminals
ST
ST
ATUS
TUS
THERMAL
THERMAL
_
+
NEGATIVE
OUTPUT
TERMINAL
POSITIVE
OUTPUT
TERMINAL