Lincoln Electric SVM159-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-36 F-36
POWER WAVE 355/405
AUXILIARY TRANSFORMER TEST (continued)
TEST PROCEDURE
1. Remove input power to the POWER WAVE
355/405.
2. Using a 5/16” nut driver, remove the case
wraparound cover.
3. Perform the Input Capacitor Discharge
Procedure detailed earlier in this section.
4. Locate the auxiliary transformer. See Figure
F.10.
5. Locate the secondary leads and plug P52.
See Figure F.10 and F.11.
FIGURE F.10 Auxiliary Transformer
FIGURE F.11 Plug Lead Connections Viewed From Transformer Lead Side of Plug
WARN ING
REMO TE
POWE R
OFF
ON
Auxiliary
Transformer
Secondary Lead
Plugs P52
STATUS
THERMAL
LINCOLN
ELECTRIC
Com 2
532
PW405
Only
(220V)
(115V)
(31)
Plug P52