ACCESSORIESC-6
LN-7 GMA WIRE FEEDER
K480 INPUT CABLE
The K480 input cable includes a 2/0
(67 mm
2
) weld cable with a Twist-Mate
TM
connector and a 14-pin (MS-3106A-20-
27PX) plug to be compatible with the smaller
Lincoln power sources (such as the CV-300).
The K480 is rated at 400 amps, 60% duty
cycle and is available in 10, 25, and 50 foot
(3.0, 7.6, and 15.2 m) lengths.
K584 AND K594 INPUT CABLES
The K584 input cable includes a 1/0
(53 mm
2
) electrode cable rated at 350 amps,
60% duty cycle, and the K594 input cable
includes a 3/0 (85 mm
2
) electrode cable
rated at 600 amps, 60% duty cycle. Both are
for power sources with stud output terminals
and a 14-pin control receptacle, and are
available in 10, 25, and 50 foot (3.0, 7.6, and
15.2 m) lengths.
WELDING GUNS
INNERSHIELD GUNS
The K126 gun and cable assembly is
recommended for most welding with 0.062
in. through 3/32 in. Innershield electrodes at
up to 350 amps. Install the insulated nozzle
extension (or thread protector) and the
nozzle contact tip for the stickout and
electrode size being used. (See Figure C.1.)
FIGURE C.1 – THE K126 GUN.
For heavy duty welding at up to 450 amps
and with 0.068 in. through 3/32 in.
Innershield electrode, use an appropriate
K115 or K115-45 gun and cable assembly
(See Figure C.2). Install the proper insulated
nozzle extension and contact tip for the
stickout and electrode size being used.
For welding with 7/64 in. Innershield
electrode, use a K115-3/32 with an M11474-
120 nozzle or a K115-45-3/32 with an
M11510-120 nozzle. Also install a 7/64 in.
contact tip and install the insulated nozzle
extension for the stickout being used.
NOTE: Linconditioner
TM
guns are
recommended for locations where smoke
accumulation is a problem and conventional
exhaust systems are ineffective. The
available smoke removal type Innershield
guns and vacuum units can be used in these
locations. Instructions are shipped with the
equipment.
FIGURE C.2 – THE K115 AND
K115-45 GUNS.