The wire feeds but starts and stops
intermittently.
TROUBLESHOOTING AND REPAIR
LN-7 GMA WIRE FEEDER
F-11
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
1. The gun trigger may be faulty.
Check or replace.
2. Check for mechanical
restrictions in the wire feed
path.
RECOMMENDED
COURSE OF ACTION
1. The drive motor brushes may
be faulty. Check and replace if
less than 1/4 in. in length.
2. The wire feed speed
potentiometer may be faulty.
Check the resistance of the
potentiometer over the entire
range of travel. The potentio-
meter should adjust from 0 to
10K Ohms. If adjustment is not
smooth and linear, replace per
Wire Feed Speed Potentio-
meter Replacement procedure.
3. The Control PC Board may be
faulty. Replace.