PART OF
MAIN WIRE
HARNESS
TIE
WRAPS
GROUND
WIRE
REED
SWITCH
LN-7 GMA WIRE FEEDER
TROUBLESHOOTING AND REPAIRF-28
GROUND LEAD PROTECTOR
REED SWITCH REPLACEMENT
(continued)
FIGURE F.7 – REED SWITCH REPLACEMENT.
REPAIR PROCEDURE
1. Remove the cover from the control box
by removing the four 5/16 in. screws
from the top and side of the unit.
2. Unplug the two wire connectors that
connect the reed switch to the wire
feeder main wire harness. See Figure
F.7.
3. Cut the two tie wraps that attach the
reed switch to the case of the wire
feeder, and the tie wrap that attaches
the reed switch leads to the main wire
harness.
4. Slide the reed switch out of the loop
formed by the ground wire and remove
the reed switch from the wire feeder. Do
not undo the loop in the ground wire.
5. Slide the new reed switch into the loop
of the ground wire. Ensure that the loop
in the wire is snug around the reed
switch.
6. Attach the reed switch to the plastic
mounts on the case of the wire feeder
using two tie wraps. The tie wraps
should also secure the ground lead in
place.
7. Connect the two wire connectors on the
reed switch to the wire feeder main
harness. Tie wrap the leads to the main
wire harness.
8. Reinstall the cover on the wire feeder
using four hex head screws.