Miller Electric Welder Welding System User Manual


 
OM-196 188 Page 97
1 Start Parameters Display
Parameter ranges are as follows:
Seconds, 0-2.5 Sec. If value set is
zero (0), there is no Run-In se-
quence. With zero (0) time value,
programmed values for volts and
wire feed speed are used until a val-
id arc condition is detected.
Volts, 10.0-38.0 Volts
Wire Feed Speed, 50-780 inches
per minute, IPM
Go on to Section 11-5.
1
> Start
24.0 Volt
90 IPM
0.2 Sec
Start
> 18.0 Volt
90 IPM
0.2 Sec
Start
18.0 Volt
200 IPM
> 0.5 Sec
11-4. Setting Start Sequence Display
Set Desired Time
Parameter
Select
Increase/
Decrease
Parameter
Select
Parameter
Select
Parameter
Select
Increase/
Decrease
Increase/
Decrease
Set Desired Voltage
Set Desired Wire
Feed Speed
Increase
Proceed to next Section.
Start
18.0 Volt
> 200
IPM
0.2 Sec
Start
18.0 Volt
200 IPM
0.5 Sec
1 Weld Parameters Display
Parameter ranges are as follows:
Inductance, 0-99
Volts, 10.0-38.0 Volts
Wire Feed Speed, 50-780 Inches
Per Minute, IPM
Go to Section 11-6.
Weld
Induct 30
20.0 Volt
> 200 IPM
> Weld
Induct 30
20.0 Volt
420 IPM
1
Weld
> Induct 20
18.0 Volt
200 IPM
11-5. Setting Weld Sequence Display
Parameter
Select
Increase/
Decrease
Set Desired
Inductance
Increase/
Decrease
Set Desired Wire Feed Speed
Increase
Proceed to next Section.
Weld
> Induct 30
18.0 Volt
200 IPM
Set Desired
Voltage
Increase/
Decrease
Weld
Induct 20
> 18.0 Volt
200 IPM
Weld
Induct 30
> 20.0 Volt
200 IPM
Parameter
Select
Weld
Induct 30
20.0 Volt
420 IPM
> Weld
Induct 20
18.0 Volt
200 IPM
Parameter
Select
Parameter
Select